GROUNDWATER FLOW INTO A WELL
SI/Metric Units
INPUT DATA
Title
Aquifer thickness, H
m
    
Transmissivity, K
m
2
/day
Storativity, S
Well flow rate, Q
m
3
/day
Distance from well, r
m
Time, t
days
RESULTS
Variables
Values
Units
♦ Well function parameter, u
2.09E-4
♦ Well function, W(u)
7.89643
♦ Drawdown, s
5.72685
m
Drawdown Vs Distance